Robinair high tank pressure. The unit includes a 1.5 cfm (42 l/m) Robinair high vacuum pu...

• Works with Robinair 34788, 34788-H, and 34988 A/C RRR Ma

Feb 10, 2013 · 5. Connect the high and low side hoses to the A/C system, and open the coupler<br /> valves.<br /> 6. Put the Low Side Valve in the Recover/Vacuum position. Put the High Side<br /> Valve in the Recover/Vacuum position. Press START to continue.<br /> 7. If the system pressure is below 25 psi, the display reads: LOW SYSTEM<br /> Robinair AC590 - User Manual - Free download as PDF File (.pdf), Text File (.txt) or read online for free. ... Inside tank pressure meter. 15. High pression valve. 16. Low pression valve. 17. Printer (optional). 18. Main power switch. 19. High side connection hose. 20. Low side connection hose.All new proprietary "Oil-less" compressor and 1/2 hp motor. Field serviceable compressor. Multi-refrigerant capable with Self-Clearing feature, which prevents cross-contamination. One 60" hose included. 1/4" MFL fittings. Optional Float Cable provides automatic shut off when tanks are 80% full. Power Source - 115V 60 Hz.Single ROBINAIR 539993 HARNESS,GROUND RA20008-1 Robinair Ferrule and Nut 1/8 Inch( 1 Piece) ROBINAIR 523149 OIL BOTTLE MEDAL CAP (1) ROBINAIR 120225 TUBE 1/4 OD X 0.040 WALL RA20005 Robinair 3/8 High Pressure Tube 18 Inches Long ROBINAIR 539654 TEE, MALE BRANCH 1/8 NPTF ROBINAIR 13203 ONE QUART …Robinair 34788ni = high tank pressure Posted to Tool & Equipment Forum on 7/15/2017 5 Replies Hey guys, good start to a saturday morning! brand new 34788ni used once before this morning. had 3 ac jobs scheduled for the day, recovered one no problem, hooked to the second one and started recover and walked away for a bit. come back itsdown when the storage tank reaches 80% capacity if the float cable is used correctly. Use only Robinair tank p/n 17990 with this machine. Shut-off Switch This unit has an internal, high-pressure, shut-off switch. If system pressure rises above 435 psi, the unit shuts off. The shut-off switch automatically resets itself afterWe stock many common replacement parts including High / Low Side Couplers, Hoses, Filters, Tank Fill Adapters, Oil Bottles, Solenoids, Dust Covers and more. Products search. Parts & Breakdowns. ... Home Replacement Parts A/C Machines Robinair 34788NI Parts. Robinair 34788NI Parts. 16103 - Flat-Free Wheel quantity. 16103 - Flat-Free WheelPour 6 ounces of vacuum-pump oil into the fill port. Press the "Start/Yes" button. As the pump is processing, slowly add more oil until the level rises to the middle of the reservoir. Press the "Stop/No" button. Reattach the plastic plug on the fill port. The Robinair 34700Z is an automotive air-conditioning service machine.Sep 26, 2014 · Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent. Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions. Set the beeper tone to high (Beeper 1), low (Beeper 2) or none (Mute). Service Menu Robinair service center use only. Hose Flush Flushes any residual oil from the unit for service of vehicles with different oils. Display Tank Info Displays internal storage vessel (ISV) pressure and temperature. Use to check the ISV for excessive pressure. Stop ... I have a robinaire ac34288 and i get a high pressure message when recover and tank refill. Ask an Expert. Home Improvement Questions. HVAC Questions. i have a robinaire …If you need to service the A/C systems of vehicles that use the new R-1234yf refrigerant, you need the Robinair AC1234-9, a fully automatic and connected machine that offers high accuracy, efficiency and reliability. Download the instruction manual in PDF format and learn how to operate, maintain and troubleshoot this advanced device.YES button is pressed. Verify the high- and low-side hoses are connected and the coupler valves are open. Press STOP / NO to exit at this point. To ensure complete recovery of refrigerant, the unit will automatically wait 5 minutes and monitor for a rise in pressure above 0 in. Hg. Note: The high- and low-side lights on the controlcompressors and the high-voltage electric compressors found on hybrid vehicles, the internal oil charge feature has been removed, and both service hose flush and vehicle A/C system flush features have been added. The unit includes a 1.5 cfm (42 l/m) high-vacuum pump for fast, thorough evacuation. The compressor pulls the A/C• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or nationalPRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. Do not overfill the internal storage vessel, ... The unit includes a 1.5 cfm (42 l/m) Robinair high vacuum pump for fast, thorough evacuation. The compressor pulls the A/C system to 0 psig ... and high-side pressure. power Cord. 543175 Rev. F, February 15, 2010 3 Introduction Keypad FunctionsThe World of Tanks game is a popular online multiplayer game that has been around since 2010. It’s a free-to-play game, which means anyone can jump in and start playing without spending any money.80211VCI refrigerant capacity database activation instructions. R-1234yf vs R-134a Robinair machine comparison (2001_541) Robinair 134a A/C Machine Comparison Chart (Document # 16-74) SDS high vacuum pump oil Document # 552184) 34788NI, 34788NI-H, 34788NI-230 Operating Instructions - English (Document # 573104)Robinair 34788ni = high tank pressure. Posted to Tool & Equipment Forum on 7/15/2017 5 Replies. Hey guys, good start to a saturday morning! brand new 34788ni used once before this morning. had 3 ac jobs scheduled for the day, recovered one no problem, hooked to the second one and started recover and walked away for a bit. come back its ... This is a common problem of Robinair 34700Z / 347002K & 347112K series machine. So don't worry just do the following, with POWER SWITCH OFF: - 1# Open front panel cover …16301 Robinair Low Side Tank Adapter 1/2" ACME Female x Low-Side R-134a Coupler ... 522975 Robinair 116" High Side Enviro-Guard Hose Coupler Set R134A. ... Clearly marked for R-134a. 740 psi working pressure, 3700 psi burst pressure. Fittings are 7/16" Flare x 14MM Hose for Automotive R-134a. Price $147.10 .ROBINAIR.COM 800.533.6127 Protect Your Investment Robinair technical support, local service centers and flexible ToolGuard™ extended service coverage you can count on. At Bosch Automotive Service Solutions Inc., we recognize that your purchase of Robinair tools and equipment is an important investment in your business. • Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or nationalRobinair 34788ni high tank pressure Robinair 34788ni = high tank pressure Posted to Tool & Equipment Forum on 7/15/2017 5 Replies Hey guys, good start to a saturday morning! brand new 34788ni used once before this morning. had 3 ac jobs scheduled for the day, recovered one no problem, hooked to the second one and started recover and …High tank pressure screen keeps showing up. Posted by Kenneth Sarratt on Jan 09, 2023. 1 Answer. OffroadCarMaster. Contributor. 15 Answers. To manually purge …HIGH PRESSURE RECOVERY UNIT, 115 60 HZ FOR MEDIUM AND HIGH PRESSURE REFRIGERANTS | Robinair. 25175B. HIGH PRESSURE RECOVERY UNIT, 115 60 HZ …17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack). Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings. Price $12.50. Add To Cart. 17916 Robinair Temp Probe Red 15ft ACR2000 ACR2005 342000.5. Connect a hose from the liquid (low pressure) side of the manifold gauge set to the liquid side of the system being serviced. 6. Connect a hose from the vapor (high) side of the manifold gauge set to the vapor side of the system being serviced. RG6 with SK-5001 kit installed: Attach tank connection harness (No. 549977) to floatI have a robinair 34788 that will not recover looking for ... I have a Robinair 34288NI, after doing the source tank refill this past Friday when I try to recover a system it says on ... i have a robinair 34288 machine that shows high pressure on the low side guage and will not recover due to the high pressure reading,i manually cleared the ...For Robinair service center use only. Menu Choice: Calibration Check Use to verify internal scale calibration. Refer to instructions in Maintenance section under Scale Calibration Check. Menu Choice: Adjust Tank Fill Lvl During the tank refill process, the unit stops refilling when it reaches the pre-set amount of refrigerant in the internal Robinair cannot know, evaluate, or advise as to all possible hazards. The user must verify that conditions and procedures do not jeopardize personal safety. Explanation of Safety Decals Used on the Machine Carefully read the instructions. Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating ...View online (41 pages) or download PDF (3 MB) Robinair 34788NI-H, 34788NI, 34788NI-230 Operating manual • 34788NI-H, 34788NI, ... HIGH TANK PRESSURE. INLET PRESSURE IS TOO . HIGH FOR VACUUM. 68 kg (150 lb) or more refrigerant has been recovered since last filter change.13169 Robinair 13169 Robinair Spin-On Filter Maintenance Kit With 34430 Recycling Filter Drier. Contains one quick change filter-drier to be used on both R-12 and R-134a stations, and one 16 ounce bottle of our Premium High Vacuum Pump Oil. For early models using 34430 Filter-Drier (17700A, 34700, 34300-2K). See your instruction manual if you ...Automatic air purge - removes potential of air accumulating in the internal tank Yes Yes Yes Vacuum Leak Test and Monitoring Yes Yes Yes Display: Multilingual. 5.7” 960x240 QVGA color LCD Yes, 4.3” 480x272 QVGA Color LCD Yes, 10.5" hi-res touch screen Refrigerant charging High, low or both sides High, low or both sides High, low or both sidesRobinair cannot know, evaluate, or advise as to all possible hazards. The user must verify that conditions and procedures do not jeopardize personal safety. Explanation of Safety Decals Used on the Machine Carefully read the instructions. Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating ... 80211VCI refrigerant capacity database activation instructions. R-1234yf vs R-134a Robinair machine comparison (2001_541) Robinair 134a A/C Machine Comparison Chart (Document # 16-74) SDS high vacuum pump oil Document # 552184) 34788NI, 34788NI-H, 34788NI-230 Operating Instructions - English (Document # 573104) Buy Now!New Fuel Tank Pressure Sensor from 1AAuto.com http://1aau.to/ia/1AEFF00018In this video, 1A Auto shows you how to repair, install, fix, change or rep...Price $21.72. Add To Cart. 17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack) 17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack). Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings.I have a Robinair 34288NI, after doing the source tank refill this past Friday when I try to recover a system it says on low side clear in ... i have a robinair 34288 machine that shows high pressure on the low side guage and will not recover due to the high pressure reading,i manually cleared the low side hose and got the pressure to ...Informs user if tank is full or has high pressure. Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center. Discontinued RA19408 Robinair 115v 100CFM Fan 115v 100CFM Fan Cooling fan positioned to pull air into front of unit across condenser and compressor and discharge it through top of unit.View online (41 pages) or download PDF (3 MB) Robinair 34788NI-H, 34788NI, 34788NI-230 Operating manual • 34788NI-H, 34788NI, ... HIGH TANK PRESSURE. INLET PRESSURE IS TOO . HIGH FOR VACUUM. 68 kg (150 lb) or more refrigerant has been recovered since last filter change.11745 Robinair High Side Refrigerant Manifold Gauge R134A/R404A/R507 0 To 500 Psi/Bar pressure readings, ... Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings. ... Pressure (high side, red) 2-1/2" gauge for r-410a only.Vacuum Timed Leak Test eliminates the need to pressure test before charging; Voltage: 115V / 60Hz Container: On-board 30 Ib (14kg) vessel (source tank not included) Operating Range: 50° to 120° F (11 to 49C) Recycling Filter-Drier: 43 cu. in. (710 cc) Spin-on type Pump Free Air Displacement: 6 cfm (142 L/m)To calibrate the scale on Robinair 34288, follow these steps: Turn off the machine and make sure that the scale is empty. Press and hold the "Weight" button for three seconds until "CAL" appears on the display. Place a weight of known mass (such as a 50-pound weight) onto the scale and press the "Weight" button.Advertisement If you want to really get your toilet tank clean, then you need to make sure you have the right cleaning products for the job. Vinegar is a great toilet cleaning solution. Not only is it free of chemicals and naturally antibac...Here are the steps to adjust the contrast on the Robinair 34788: Turn on the machine and wait for the display to fully light up. Press and hold the "Enter" and "Clear" buttons simultaneously for three seconds. The display will show "Contrast" and the current contrast setting. Use the "+" and "-" buttons to adjust the contrast to your desired level. View online (41 pages) or download PDF (3 MB) Robinair 34788NI-H, 34788NI, 34788NI-230 Operating manual • 34788NI-H, 34788NI, ... HIGH TANK PRESSURE. INLET PRESSURE IS TOO . HIGH FOR VACUUM. 68 kg (150 lb) or more refrigerant has been recovered since last filter change.50 lb. Recovery Tank w/ Float Sensor (R134a) Our Price: $344.46 . A/C Cord Our Price: $35 ... Coupler Seal High Side Our Price: $3.50 . Coupler Seal Low Side Our Price: $3.50 . Cubigel RL90TE Compressor for Robinair Our Price: $389.95 . Cubigel RL90TE Compressor for Robinair Our Price: $389.95 . DOOR LATCH Our Price: $32.95 . Filter …124015 Robinair High Pressure Wire Harness 348002K Post 30000 Serial Number. Connects high pressure switch to main board. Board connection P11. Price $11.95 . 13172 Robinair Filter Pump Oil Maintenance Kit With 34724 Filter ...19740 Robinair Source Tank Filter For 134A 115642 Robinair 12oz. Oil Drain - Oil Injector Bottle ... 522975 Robinair 116" High Side Enviro-Guard Hose Coupler Set ...• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or nationalPropane tank pressure ranges from about 100 to 200 pounds per square inch. The size of the tank does not influence the pressure that the propane is under. The outside temperature and the temperature of the propane in the tank can cause pres...After the vacuum pump shuts off, connect the fill hose to the liquid connector on a full source tank. 3. Open the source tank valve. 4. Install the source tank, and secure it to the unit (using the tank strap) in such a way that liquid refrigerant is supplied to the connection. 5. Press START / YES to begin filling the internal storage vessel ...Here are the steps to adjust the contrast on the Robinair 34788: Turn on the machine and wait for the display to fully light up. Press and hold the "Enter" and "Clear" buttons simultaneously for three seconds. The display will show "Contrast" and the current contrast setting. Use the "+" and "-" buttons to adjust the contrast to your desired level.The fuel system within your vehicle is a complicated collection of many parts, including fuel injection lines, fuel tank, filters and pumps. All of these parts must be working together for the car to run properly. When any one of these part...1. Check for pressure on gauges. 2. Checks the service couplers are open. 3. Check tank valve are open. 4. Check that the compressor is running. 5. Check tank pressure and purge tank if needed. Air purge in maintenance menu. 6. Close liquid ball valve on tank filter. If recovery then happens the charge . solenoid valve has dirt in valve.Thanks for taking the time to watch our videos. If you have any questions let us know. We are here to help you to learn how to do HVAC service & things like ...Price $21.72. Add To Cart. 17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack) 17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack). Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings. Price $12.50.25litres Electric Air Compressor +1 2 Promoted Posted 3 hours Lagos, Ojo 27 views Brand New Condition Other Make Make Other Model Model Other Type Store address Show 1 options Lagos State • Ojo Lagos, Ojo alaba market Closed • Mon - Sat, 09:30-17:30 Hide options Electric air compressor machine 25litres tank 2horsepower engine Show• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or national source tank. (For R-134a, use quick-coupler adapter No. 116121; for R-12, use the 6" yellow adapter No. 710778. Both are included with unit.) NOTE: If using a refillable tank, install the tank upside down, and connect the low-side service hose to the vapor valve. 8. Open the tank valve and invert the tank. Press START when finished. 9.17572 — 50 lb. tank with float switch 19776 Optional Accessories Part No. 30Lb (14kg) Recovery Tank 17121 30Lb (14kg) Recovery Tank with 80% capacity sensor 17605 50Lb (23kg) Recovery Tank 17506 50Lb (23kg) Recovery Tank with 80% capacity sensor 17572 50Lb (23kg) High Pressure Recovery Tank with 80% capacity sensor (use with R-410A) RGT50HP Robinair introduces its next innovation, the 34788NI-H, featuring an industry leading 98.5% recovery efficiency for standard and hybrid vehicles and fully automatic function. The Robinair 34788NI-H machines recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5% efficiency – unmatched by any competitor. Robinair cannot know, evaluate, and advise you as to all possible hazards. You must verify that conditions and procedures do not jeopardize your personal safety. Explanation of Safety Decals Used on the 34788NI/34788NI-H. Carefully read the instructions. Do not use in open air in case of rain or high hu-midity. Wear gloves. Wear protection goggles.Machine is locked out because pressure in ISV is too high, possibly because of excessively high tank temperature. Before the machine begins evacuating the A/C system, it checks for pressure in the system that could damage the vacuum pump. In this case, system pressure is above 0.35 bar gauge. Not enough refrigerant in the ISV to perform a ...ROBINAIR.COM 800.533.6127 Recover, Recycle, Recharge Machine for R-134a A/C Systems ... Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating voltage. ... use only type-approved refillable containers that have pressure relief valves. HOSES CAN CONTAIN LIQUID REFRIGERANT UNDER …RA19104 Robinair High Pressure Cutout 435 PSI High Pressure Cutout 17650 / 17655 A normally closed sensor that opens, stopping the recovery process when the compressor discharge pressure reaches 435 psi. SPDT Contact arrangement. 1/4 spade termination. Robinair does not warrant any "RA" repair item not installed by an Authorized Service …Get a replacement hose for your Robinair or Snap-on A/C Machine. We carry high and low side hoses for R134 refrigerant and more.. 1. First ensure that pressure does not exist in the liRobinair No. 34788NI/34788NI-H is equipped with the foll • Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or national According to Flotec, a manufacturer of water well and water pumping equipment, the water well pressure tank is a storage tank that prevents the well pump from turning on and shutting off repeatedly by using air pressure to maintain water pr... i have a robinair a/c machine 34788-h that will not work anymore RA19427 Robinair High Pressure Switch High Pressure Switch If pressure inside the unit exceeds 435psi, the switch opens, stopping all functions of unit. NOTE: Switch opens at 435psi +/- 10psi and resets at 320psi +/- 20psi. Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.combustible at elevated pressures. These mixtures, if ignited, may cause injury or property damage. TO PREVENT CROSS-CONTAMINATION, USE THIS UNIT WITH R-134a REFRIGERANT ONLY. The unit is designed to recover, recycle, and recharge only R-134a refrigerant. Do not attempt to adapt the unit for another refrigerant. compressors and the high-voltage electric compressors ...

Continue Reading